Features
|
-
Dual Channel and Auto Calibration.
-
DC to 1MHz Oscilloscope band width
-
Sampling Time * Dual CH mode: 25 Ms/S * Single CH mode: 50 Ms/S
-
Automatic Triggering.
-
Automatic setting for horizontal and vertical division
-
Roll and Single shot mode
-
Excellent internal noise reduction
-
Real time Update.
-
Auto ranging.
-
45 shot reference waveform and setup memories
-
Built-in auto ranging True-RMS digital multi-meter
-
Data hold and run mode.
-
Extra Bright Back light display
-
Low battery indication.
-
Max. Voltage between any Input and Ground: DC or AC 600Vpeak
-
RS-232 interfaces for transferring measurement data and waveform.
-
Display Type: Super-Twist 132 x 128 pixels
-
Designed to comply with safety standard for UL3111, CSA C22.2 No.1010-1
|
|
|
Sample Rate |
25 Meg-samples per second (Dual CH mode) |
50 Meg-samples per second (Single CH mode) |
Record Length |
512 in single shot and glitch capture mode 256 in all other modes. |
Sample / Division |
25 |
Update Rate |
Real time |
Modes |
Single shot, Roll, Normal |
Accuracy |
0.01% |
Sweep Rate |
1uS to 5S in 1, 2, 5 sequence |
|
Bandwidth |
1MHz |
Resolution |
8 Bit |
Channels |
Dual |
Coupling |
AC, DC |
Input impedance |
1 MΩ |
Accuracy |
3% |
Max. Input Volts |
DC or AC 600Vp-p |
Volt / Division |
0.5V to 500V in 1, 2, 5 sequence |
|
Type |
Internal |
Coupling |
AC, DC |
Slope |
Rising or Falling edge |
Internal Trigger Sensitivity |
2 / 20 Division |
|
Wave Form Memory |
8 Shot |
REF Wave From Memory |
45 Shot |
|
Digital Multi-Meter Function
|
Range |
Resolution |
Accuracy |
Impedance |
5V |
0.001V |
± (0.3% +3) |
1 MΩ |
50V |
0.01V |
500V |
0.1V |
1000V |
1V |
|
Range |
Resolution |
Accuracy |
Impedance |
50Hz~450Hz |
0.45kHz~5kHz |
5kHz~20kHz |
3V |
0.001V |
± (0.75%+5) |
± (2%+5) |
± (2.5%+5) |
1 MΩ |
30V |
0.01V |
300V |
0.1V |
750V |
1V |
N/A |
|
Range |
Resolution |
Accuracy |
Over Load Protection |
5 kΩ |
0.001 kΩ |
± (0.5% +5) |
600V DC or AC Peak |
50 kΩ |
0.01 kΩ |
500 kΩ |
0.1 kΩ |
5 MΩ |
0.001 MΩ |
± (1% +10) |
|
Test Voltage |
Threshold |
Over Load Protection |
1.7V
|
100 digits |
600V DC or AC Peak |
|
Function |
Range |
Resolution |
Accuracy |
RPM |
240~60,000 |
1RPM |
± (0.5% +5) |
% Duty, Cycle |
25% ~ 75% (30 RPM to 19,000 RPM, Pulse Width > 0.5mS) |
Dwell |
0.3 ~ 352.8° (30 RPM to 19,000 RPM, Pulse Width > 0.5mS) |
Pulse Width |
0.2 ~ 1999.9mS (30 RPM to 19,000 RPM, Pulse Width > 0.5mS) |
Frequency |
2~ 1MHz (30 RPM to 19,000 RPM, Pulse Width > 0.5mS) |
|
Power Requirement |
9V 6F22 x 2 |
Dimension |
90(W) x 190(D) x 32(H) mm |
Weight |
Approx. 260g |
|
|
|
1. Users Manual 2. Test Leads 3. Ni-MH Battery Pack (Installed) 4. AC Power & Rechargeable Adaptor 5. Rubber Holster 6. Carrying Case 7. RS232 Cable 8. RS232 Program Diskette 9. Inductive Pick-up. 10. Capacitance Pick-up.
|
|